Specifications include, but are not limited to: 1. Demolition o Contractor responsible for demolition and removal of temporary flashing, Collection Boxes, Downspouts, as well as any other materials required for the installation of new cornices. 2. Carpentry o Install new wood structural supports for cornice. o All lumber used in the project must be pressure treated #1 ground contact and fastened with stainless steel o All carpentry work will be done to the best standards and practices 3. Masonry o Mortar to be used is Holcomb Type N or equivalent, contractor to provide mortar color samples to match existing mortar to be approved by the owner. o Contractor responsible for all pointing behind cornices and other areas where needed for flashing o All masonry work will be done to the best standards and practices