Specifications include, but are not limited to: FD5S would like to reduce the quantity of fixture types across all schools and standardize the color temperature of all exterior fixtures to 5000K. GENERAL REQUIREMENTS FOR EXTERIOR FIXTURES AND LAMPS Fixture current shall be less than or equal to the replaced fixture unless proven acceptable by analysis provided by Vendor. All exterior fixtures and replacement lamps shall be 5000K CCT. If installation requires specialized mounting hardware, those shall be supplied and included in the base bid. WALL MOUNT A Approximate Count – 50 Fixtures Replacement Fixture Requirements Fixture lumen output range of 2500-3000 lumens Maximum input Power of 30W Minimum L70 rated life of 50,000 hours Minimum CRI of 70 Must be UL Wet Location rated. Full fixture replacement warranty of no less than 5 years. Must be listed on the Design Lights Consortium (DLC) Qualified Products List. Fixture must be able to be subjected to 1,000 hour salt-spray test, with rib reinforced construction and integral heat sinks. Four tamperproof tools will be provided to the Owner for each type of tamperproof screw installed. LENS (IF Utilized): UV-stabilized, high impact resistant, injection molded clear textured 100% DR acrylic or polycarbonate lens. Minimum 5-year warranty covering full cost of replacement.