Specifications include, but are not limited to: Water will be supplied from an existing pump station with variable speed drive, rated at 425 GPM @ 332-ft TDH, through approximately 450 LF of existing 6-in PVC, which shall be extended by Clemson University to the new pivot point (approximately 700 LF based on pivot point shown in Appendix A). 3) It is anticipated this system will cover a radius of approximately 1450 ft and will need to cover approximately 75 acres in a part-circle. The system shall run completely on 480V electric (no hydraulic) power. The system shall include a Variable Rate Irrigation controller with individual nozzle control. VRI should have capability for loading irrigation prescription maps, accepting input from in-field moisture sensors, and integrating with smartphone and desktop computer control applications.