Specifications include, but are not limited to: The Archives Vault room must have access controls and must be designed as an access-controlled area with only two (2) entrances that can be secured from the rest of the building. a. Archives Vault must have direct access to the Reading Room and staff offices. b. There must be two entry ways from the Archives Vault Room to other parts of the archival area ; B. A security camera should be located at each entrance to this space. C. The Archives Vault room must have ceilings of a minimum of 12-feet in height. D. The floor must be reinforced concrete with an epoxy finish with high loadbearing capacity for the weight of holdings. Archives Vault will contain rows of heavy-duty shelving. ; Lighting must be motion activated in Archives Vault. Normal light levels must provide at least 200 Lux, but not more than 500 Lux measured 36 inches above the floor level. Levels of ultraviolet radiation must not exceed 10 microwatts/lumen. ; A. The minimum continuous temperature in the Archives Vault shall be 55 degrees Fahrenheit. B. The maximum continuous temperature in the Archives Vault shall be 65 degrees Fahrenheit.