Specifications include, but are not limited to: . Incinerator shall be able to be permanently installed outdoors on a concrete pad and capable of operating in an outdoor temperature range of 0 to 110 degrees Fahrenheit. 1. Fuel type. a. Incinerator shall operate using Diesel Fuel 2. Electrical. a. Incinerator shall require 120VAC or 220VAC for electrical hook up 3. Size. a. Maximum dimensions of incinerator shall not exceed 8 foot in length and 4 foot in width 4. Burn Chambers. a. Incinerator shall have dual burn chambers (primary and secondary) b. Each burn chamber shall have its own burner c. Primary and secondary burn chambers shall be of the same volume and be no less than 8 cubic foot capacity d. Burn chamber lining shall be replaceable e. Incinerator shall be capable of burning a minimum of 50 pounds of regulated garbage per one hour of operation 5. System and features. a. Incinerator shall be fully automatic operation from start up, through the burn process, to shut down b. Incinerator shall have a temperature monitoring system.