Specifications include, but are not limited to: The computerized central control system is specified Rain Bird IC System or approved Equal with Stratus central control/software operating on Microsoft Windows 7 or 10 Professional operating software and capable of controlling integrated control modules through an integrated control interface. The central platform is to provide automatic control of flow dynamics with single station control. The system shall be a basic low voltage communication path between the interface output module and the sprinklers and meet NEC Code for circuits not more than 30 volts. The control system shall have a hydraulic management feature, which shall provide for the establishing of flow limits for the entire piping network and entering maximum flows. The system shall also provide for the entering of data according to the pumping system operating characteristics. Each established pipe, in the piping network, shall be assured that the demand will never exceed the design capacity, either by gallons per minute or velocity. The irrigation cycle itself, will be completed in the shortest possible running time, resulting in the least amount of wear and tear on the pumps, less maintenance costs, longer pump life, reduced power costs, etc. The results shall be that the entire system may be operated on the hydraulic manager, maintaining full load demand on the pumping system, for as much of the cycle as possible, while not allowing over demand on any portion of the piping network.