Specifications include, but are not limited to: All instrumentation and industrial electronic systems shall be provided under the supervision of a single systems integrator, which is regularly engaged in the design and installation of such systems of similar scope and complexity. E.Coli Monitor – Optical Type CFU/100ml 120 VAC, Optional 12V E. Coli measurement system shall be designed for precise continuous, online monitoring of E. Coli in wastewater using a fluorescence type sensor with a dedicated analyzer/transmitter. The E. Coli measurement system shall include the sensor, analyzer transmitter, the sensor connection cable, control panel, any required termination boxes, and mounting hardware. The sensor connection cable between the sensor and the analyzer transmitter shall be provided by the system manufacturer. A sufficient length of tubing shall be provided for installation of a continuous run between the sensor chamber and the transmitter. Transmitters, terminal modules, junction box modules, cabling, power modules, and mounting kits shall be provided as required to provide a complete and operating system.