Specifications include, but are not limited to: Hardware Requirements 1. Keyless interface must have keypad and either fob or swipe card capability 2. Exterior installations must be weather tight Network Requirements 1. Must use a network connection TCP/IP 2. Product cannot use Telnet 3. Software must be able to operate in a VMWARE environment 4. Packets must be able to pass over a site to site VPN 5. Network traffic must be able to pass at layer 2 and layer 3 6. Access control system will use encryption or GRE tunnels Software Requirements 1. Software must be intuitive and user friendly 2. Must allow multiple schedules at different locations including holiday schedules 3. Must allow a “first entry” option to unlock doors during scheduled hours of operation 4. Must allow simple lock down options for the all doors as well as for individual locations 5. Must accommodate multiple levels of administrative users 6. Compatible with Windows 2012 Server or newer Installation Requirements 1. Parallel installation with existing system required so that access control is maintained at each door during install. 2. Work to commence as soon as possible after award and to be substantially complete by March 31, 2020.