Specifications include, but are not limited to: Four Cat6A data drops will be installed (run) from an IDF or MDF network closet to the agreed upon end locations in each of the thirty-four (34) classrooms (total 136 drops) (Projector, Access-Point, Switch, SmartBoard Wall). See Appendix B for list of rooms. Eighteen(18) Cat6A data drops will be installed from a designated IDF or MDF network closet to the agreed upon end locations. See Appendix C for list of locations. Service loops are required: 10 inches at classroom and 10 feet at IDF/MDF Wires must be fished through the wall for classrooms. Approximate Locations of Classroom Data Drops One data drop at the existing fiber drop/or switch location One data drop terminated in a box in the middle of the room for an access point in the ceiling. Drop to be installed in a biscuit box (plenum rated). One Data drop terminated in a box near where the projector attaches to wall or ceiling. - (When Ceiling Mounted Projector is present) When No Projector is present in a Classroom within the room another location will be designated One Data drop terminated and installed on the same wall as the Smart-Board. (within 18’ of A/V Plate) or designated location Exact locations can be determined during a walk-through