Specifications include, but are not limited to: • Concrete slab on grade construction with trench footings. • Load bearing steel stud construction with steel frame at double height areas. • Roof system comprised of steel trusses and steel bar joists, with tapered insulation and TPO roof. • Exterior skin to be terra cotta tile and heat-treated acetylated wood. • HVAC to be a high efficiency Variable Refrigerant Flow system. • High durability finishes • Facility will include numerous "smart sustainable" features, including an innovative dashboard to remotely monitor energy and water usage. In addition, a priority has been placed on innovation related to firefighter health, resulting in sensors to measure a variety of toxins, actively displayed on the dashboard. • An innovative water recapture system for truck washing is also being developed to reduce usage of potable water. • Site features to include an access road extension, and regrading of the sloped site to accept the new facility and landscape features.