Specifications include, but are not limited to: The contractor shall be responsible for installation, maintenance, and repair of all equipment and wiring up to and including the head end. The Department shall be responsible for all equipment and wiring past the head end. The contractor must furnish and maintain in good repair all equipment, including, but not limited to, dishes, antennas, TVROS, modulators, amplifiers, taps, and wiring, and any other equipment necessary to perform the requirements of the contract. a. The contractor may either own or rent, at the contractor’s expense, equipment for performing the requirements of the contract. b. Any cable/wiring installed within the facility, past the head end, becomes the property of the Department once installed. c. The repair, maintenance, and replacement of contractor supplied equipment, as necessary, shall be at no cost to the Department. d. If providing a satellite service, the contractor shall not supply more than two dishes not-to-exceed forty-two inches (42”) in diameter. If the dishes are not round, the largest dimension shall not exceed forty-two inches (42”). 1) If necessary, a third dish not to exceed forty-two inches (42”) in diameter may be utilized for the TBN Second Chance Channels. 2) The placement, method of mounting, and cable run of satellite dishes must be approved by the Department. 3) If providing satellite service and using satellite dishes forty-two inches (42”) or less, the contractor must provide heaters on the dishes with an on-off switch at the head end. e. Receivers must be properly balanced in order to minimize the possibility of channel bleed-over. f. Any additional equipment required in order to maintain the required channel selection due to signal change, changes in technology, etc., shall be the responsibility of the contractor. g. The head end rooms at the Department are air conditioned to the building settings. Any additional cooling requirements to properly maintain the equipment (i.e. rack fans) are the responsibility of the contractor, and must be per industry standards and NEC 2011 requirements. h. R-rated or above programming must not broadcast under any circumstances. Therefore, the contractor must supply the necessary equipment to block any R-rated or above programming. This shall include, but not be limited to, any trial offer previews or channels that may broadcast R-rated or above programming. i. The Department will provide sufficient space and the necessary electrical power for the system to successfully run the cable system. j. All replacement equipment must current market technology at time of installation. This includes all equipment prior to and including connection to the head end.