Specifications include, but are not limited to: Joint Seal : The gland material shall meet or exceed the following physical requirements: Property Test Method Typical Value Durometer (Shore A) ASTM D 2240 55 ± 5 Tensile (psi) ASTM D 412 550 psi min. Elongation (%) ASTM D 412 350% min. Tear (die B ppi) ASTM D 624 100 ppi min. Compression Set ASTM D 395 30% (max) At 350ºF 22 hrs. Operating Temperature Range -60°F to 350°F Specific Gravity CYCLIC LOADING TEST 1.51 ± 0.10 The Joint Seal shall be pre-qualified by undergoing and passing a CYCLIC LOADING TEST. Test Sample Length 2 feet min. Joint Skew 45° Number of Cycles 200 min. Joint Opening 2 inches Movement ± 1” Temperature -20ºF Any rips, tears, or bond failure will be cause for rejection. Manufacturer must provide documentation to verify testing meets these minimum requirements. Epoxy Primer: Epoxy primer shall be as specified by the manufacturer to insure the appropriate bond of the joint sealing system and meet the following physical requirements: Property Test Method Typical Value Viscosity (centipoise) ASTM D2196 44 Solids ASTM D4209 41 Specific Gravity ASTM D1217 0.92 Flashpoint ASTM D56 48 VOC ASTM D3960 520