Specifications include, but are not limited to: EACH,SANITARY SEWER INSPECTION 2206 LF,1" CORPORATION STOP 9 EACH,6" SADDLE 5 EACH,DUCTILE IRON FITTINGS 948 LB,CONCRETE CURB AND GUTTER DESIGN B612 246 LF,6" CONCRETE DRIVEWAY PAVEMENT 427 SY,CONIFEROUS TREE 6' HT B&B 19 TREE,STABILIZED CONSTRUCTION EXIT 1 LS,SILT FENCE, TYPE MS 2214 LF,RAPID STABILIZATION METHOD 4 2000 SY,4" SOLID LINE PAINT 85 LF,PAVEMENT MARKING SPECIAL 4060 LF,SALVAGE SIGN TYPE SPECIAL 2 EACH,SAWING BITUMINOUS PAVEMENT (FULL DEPTH) 3328 LF,18" CAS SAFETY APRON 2 EACH,15" RC PIPE SEWER DESIGN 3006 CLASS V 3424 LF,18" RC PIPE SEWER DESIGN 3006 CLASS V 914 LF,CONSTRUCT BULKHEAD 2 EACH,12" PVC PIPE SEWER 197 LF,ADJUST VALVE BOX-WATER 12 EACH,12" PVC WATERMAIN 106 LF,CONSTRUCT DRAINAGE STRUCTURE DESIGN SPECIAL 3 1 EACH,LIGHT FOUNDATION DESIGN E 33 EACH,TRAFFIC CONTROL 1 LS,REFERENCE LOCATION SIGN 1 EACH,SIGN PANELS TYPE D 294 SF,SOIL BED PREPARATION 6.3 ACRE,SEEDING 6.3 ACRE,WEED SPRAYING 3.2 ACRE,SEED MIXTURE 25-131 1244 LB,MAINT AND RESTORATION OF HAUL ROADS 1 LS,REMOVE HYDRANT 1 EACH,REMOVE SIGN TYPE C 43 EACH,SAWING CONCRETE PAVEMENT (FULL DEPTH) 63 LF,REMOVE STONE RETAINING WALL 90 LF,REMOVE CONCRETE DRIVEWAY PAVEMENT 232 SY,REMOVE BITUMINOUS DRIVEWAY PAVEMENT 7125 SY,REMOVE CONCRETE WALK 3765 SF,EXCAVATION - CHANNEL AND POND 7388 CY,AGGREGATE SURFACING CLASS 1 211 TON,WATER 100 MGAL,AGGREGATE BASE CLASS 6 18797 TON,21" RC PIPE SEWER DESIGN 3006 CLASS III 54 LF,33" RC PIPE SEWER DESIGN 3006 CLASS III 664 LF,4" PVC PIPE SEWER 153 LF,8" SADDLE 4 EACH,CONSTRUCT DRAINAGE STRUCTURE DESIGN 4007 8 EACH,CASTING ASSEMBLY 96 EACH,CONSTRUCT DRAINAGE STRUCTURE DESIGN H 50.4 LF,CONSTRUCT DRAINAGE STRUCTURE DESIGN 72-4020 17.5 LF,CONSTRUCT DRAINAGE STRUCTURE DESIGN 96-4020 16.4 LF,RANDOM RIPRAP CLASS IV 154 CY,2" RIGID STEEL CONDUIT 50 LF,TRAFFIC CONTROL SUPERVISOR 50 UDAY,INSTALL SIGN TYPE D 1 EACH,OBJECT MARKER TYPE X4-2 4 EACH,TEMPORARY FENCE 300 LF,CULVERT END CONTROLS 2 EACH,SUBSOILING 6.3 ACRE,FERTILIZER TYPE 4 143 LB,EROSION CONTROL BLANKETS CATEGORY 3N 3886 SY,SEED MIXTURE 33-361 10 LB,SEED MIXTURE 36-311 18 LB,4" SOLID LINE MULTI-COMPONENT GROUND IN (WR) 10900 LF,CONSTRUCTION SURVEYING 1 LS,MOBILIZATION 1 LS,COMBINATION FIELD LABORATORY-OFFICE 1 EACH,SALVAGE SIGN TYPE D 10 EACH,REMOVE SEWER PIPE (STORM) 702 LF,REMOVE FENCE 16 LF,REMOVE BITUMINOUS PAVEMENT 25125 SY,STREET SWEEPER (WITH PICKUP BROOM) 40 HOUR,DRILL AND GROUT REINFORCEMENT BAR (EPOXY COATED) 327 EACH,TYPE SP 9.5 WEARING COURSE MIXTURE (3,C) 3080 TON,18" RC PIPE APRON 2 EACH,CONNECT TO EXISTING STORM SEWER 2 EACH,8" PVC PIPE SEWER 2036 LF,8" PVC WATERMAIN 947 LF,CONSTRUCT CONTROL STRUCTURE 1 EACH,RANDOM RIPRAP CLASS III 60 CY.