Specifications include, but are not limited to: Not in project price: This section describes work being performed by the Regional Field Consultant (RFC). This work is not in the project price. B. This section describes air monitoring, soil sampling and surface lead dust wipe sampling carried out by the RFC to verify that the building beyond the work area and outside environment remain uncontaminated. This section also sets forth baseline levels that the Contractor must comply with, and describes the action required if the levels are exceeded. C. Corrective Work triggered by this section is part of the project price and is to be performed by the Contractor at no additional cost to the owner. D. Additional air monitoring required by OSHA is work of the Contractor and is not covered in this section. 4.2 ANALYTICAL METHODS: A. Atomic Absorption Spectroscopy or Inductively Coupled Plasma Emission Spectroscopy will be used for analysis of: 1. Surface lead dust wipe samples 2. Air Samples 3. Soil Samples 4.3 ESTABLISH BASELINE LEAD CONCENTRATION: A. Before start of work, the RFC will secure the following dust and soil samples to establish a baseline level. 1. Dust Samples: At a minimum, one sample from a floor and window sill in each work area. One floor sample from outside each work area. 2. Soil Samples: At a minimum, one Composite sample per building all sides included. 4.4 SURFACE LEAD DUST MONITORING: The purpose of the RFC's surface lead dust monitoring will be to detect faults in the work area isolation which may cause contamination of the building or exterior with lead dust. A. Should any of the above occur, cease Hazard Reduction activities. Correct fault in work area isolation or work procedures at the contractor’s expense. 4.5 SURFACE LEAD DUST CONCENTRATIONS: A. Outside Work Area: Maintain lead concentrations below baseline levels. Baseline levels will be determined by the RFC prior to the start of work. If baseline levels are exceeded, stop all hazard reduction activities, and institute corrective actions. The RFC will determine source of the high reading. 4.6 SOIL LEAD CONCENTRATIONS: A. Outside Work Area: Maintain lead concentrations at or below baseline levels. If concentrations rise above baseline levels institute corrective actions. The RFC will determine source of the high reading. 4.7 CORRECTIVE ACTIONS A. If the high reading above is outside work area, but inside building and was result of failure of work area containment measures initiate the following action: 1. Erect new critical barriers as set forth in section pertaining to work area containment. 2. Decontaminate affected area in accordance with section pertaining to project decontamination at no cost to the owner. B. If the high reading above is soil outside building and was result of failure of work area containment measures, initiate the following action: remediate soil at the Contractor’s expense.