Specifications include, but are not limited to: This quotation shall be for the masonry and door/frame work to provide a new exterior egress door located at the front right side of the building. The work involves cutting the rough opening for a new door; furnishing and installing a lintel (precast reinforced concrete lintel from an approved manufacturer, ASTM A615 for 60,000 psi reinforcement, compressive strength of 3,000 psi min. galvanized/painted steel angle, A36 or A572); cleaning and reusing the brick/split face block; placing concrete/mortar fill for masonry units; furnishing and installing the door, door frame and threshold including priming and painting of these items; and furnishing and installing panic hardware, lock/pull, and closeron the new hollow metal door. This work includes all material, labor, equipment, tools, and incidentals necessary to complete the work. The Contractor shall submit all applicable material specifications to the County representative for review and approval prior to the start of work. Please note that contractors bidding on this project shall anticipate the need to possibly modify the proposed construction schedule due to uncertainties surrounding the COVID-19 pandemic.