Specifications include, but are not limited to: Structural Frame: a. Shall consist of vertical rectangular wood posts set 4’ apart center to center or as needed to meet the required load. b. Post shall be long enough to provide internal clearance height specified in NOMINAL BUILDING DIMENSIONS. Posts may be rough lumber. i. OPTION 1 a. Vertical wall posts shall be founded and supported by a continuous cast-in-place concrete “T-Wall.” “T-Wall” shall consist of a reinforced concrete spread footing and vertical concrete column, as designed by the supplier’s engineer. Timber posts shall anchor into both the spread footing and vertical column. Only timber members shall be used in areas that come in contact with salt. Salt contact with concrete members will not be permitted. ii. OPTION 2 a. Vertical wall post sized and spaced as needed to withstand the lateral load of internal material pile at maximum height. Wall Post shall be placed in concrete footers as designed to meet the maximum required lateral load. One piece of ½” rebar shall extend thru the Wall Post and into the concrete footer. c. No bracing will be allowed on the interior that extends away from the wall and conflicts with the Owner’s equipment movements.