Mold Remediation for the Performing Arts Auditorium


Delivery Location
Lincoln Parish, LA, USA
Publication Date
03/07/2018 03:39 PM EST
Closing Date
04/11/2018 04:00 PM EDT
Issuing Organization
Grambling State University
Solicitation Number
Description

Specifications include, but are not limited to: The work area shall include the Control Room and the seating area of the Auditorium. The source of mold growth is believed to be from condensation due to mixing of air from above the Auditorium ceiling and below the sheetrock ceiling and below the drop ceiling. It is assumed at this point that the contaminated wall surfaces can be cleaned and treated, but alternate bids for removal are requested. All mold remediation work is to be done by a Louisiana Licensed Mold Remediation Contractor. Control Room  The Control Room shall be contained under negative pressure.  All contents of the Control Room shall be cleaned and disinfected with an EPA approved biocide/disinfectant.  All surfaces of the Control Room shall be cleaned and disinfected with an EPA approved biocide/disinfectant.  The HVAC ducts and supply vents in the Control Room shall be cleaned and disinfected. Auditorium  It does not appear to be feasible to place the auditorium under negative pressure.  Isolation methods to control dust away from the stage should be used which may include polyethylene sheeting and/or air scrubber configuration to control directional airflow.  Access to the building with a hydraulic lift does not appear to be feasible, and it is likely that scaffolding will need to be erected.  All ceiling tiles in the Auditorium are to be removed and discarded.  Contractor will replace all removed ceiling tiles.  All sheetrock wall and ceiling surfaces shall be cleaned and disinfected with an EPA approved biocide/disinfectant.  Wall and ceiling surfaces shall be treated with an anti-microbial primer and re-painted to match the existing paint.  Lower cinder block walls shall be cleaned and disinfected only.  The sound absorbing panels on the side walls and the flat sound panels on the back wall under the Control Room shall be HEPA vacuumed.  The sound panels on the back wall shall be treated with a biocide/disinfectant.  Auditorium carpeting and seats shall be HEPA vacuumed. Non-fabric surfaces such as cement flooring and solid components of the chairs are to be cleaned and disinfected.  The stage floor shall be mopped with a biocide/disinfectant.

Source
https://wwwcfprd.doa.louisiana.gov/osp/lapac/srchopen.cfm?deptno=all&catno=all&dateStart=&dateEnd=&compareDate=O&keywords=&keywordsCheck=all (opens in a new window)

Get instant access

to solicitation details & future business opportunities.

Get Access

Vendor packages with access to similar open solicitations

Statewide

Matching bid notifications & access to all Statewide & Group bid details

Group

Matching bid notifications from participating agencies

Basic

Access participating agency bids