Specifications include, but are not limited to: • Furnish all labor, equipment, materials, tools, and incidental items required to install VCT flooring. • VCT shall be 12in x 12 in • Adhesive shall meet factory recommendations for installing over concrete slab flooring. • VCT shall be Armstrong’s color. The maintenance department will determine the color. • Clean area as needed to provide a safe environment. • Previous vinyl flooring needs to be removed down to concrete • Contractor shall follow all prep recommendations of factory to install vct flooring. • All work shall meet local and state codes. • Contractor is responsible for measuring square footage of installation areas. The approximate floor area is 6212 square feet. • All new vinyl were it meets existing ceramic will need a metal transition installed by anchoring with appropriate fasteners. • All exterior door must have new appropriate thresholds installed.