Specifications include, but are not limited to: EOC Wall and Media Room Construction. Construction/renovation project to support GOHSEP State Emergency Operation Center's audio and visual upgrade. • Vendor must add (4) 800S200-54 w/4” or equal ,top & bottom track, add (2) 400S200-54 or equal, gang post type per dimensions (Section 1 (S1) See Attachment D) • Vendor must locate existing 3 5/8” stud and 6” stud. Remove existing gypsum board as required to install 8” box beam. Add continuous 1 ½” x 1 ½” 24 gage angle Install gypsum board or equal (as per referenced on S1/Section 1 see Attachment D), and coordinate paint color with GOHSEP. • Vendor shall install 5/8” gypsum board on both sides of extended new wall and coordinate paint color with GOHSEP. Paint partial new wall (color: Valspar paint 4005-2C Muskeg Grey or equal). Match and paint adjacent wall with existing EOC wall color to wing corners of walls and from ceiling to floor. • Vendor shall install 5/8" Paint-Grade Hardwood Plywood to be installed over existing gypsum board wall (Reference Attachment D: to see S1 drawing for dimensions of plywood installation) using #12 x 2” self-tapping Tek screw type or equal. Paint wood trim around perimeter to close off raw edge of plywood and coordinate paint color with GOHSEP. • Vendor to adjust lay-in ceiling system and floor finishes as required, accommodating the new construction.