Specifications include, but are not limited to: • Delivery of an approximate sixty (60) feet by ten (10) feet new scale to job site and must fit existing opening • The scale shall be in three (3) twenty (20) feet sections • Removal of the old sixty-foot scale (three 20-foot sections) and placing said sections off to the side and out of the way of traffic • Installation of new scale into the current location of existing scale • Running all new wires, cables, etc. from the scale house to the scales as to ensure operation of scale • Providing and ensuring that the scale digital indicator works with the software that will be in use in the scale house • The deck shall be a steel deck • The deck shall have a concentrated load capacity of at least 100,000 pounds • The deck shall have a covering to prevent or slow rusting • Shall have access cover plates in order to clean lead cell area of debris • Scale shall be calibrated prior to beginning operations • Software and hardware to be provided by the City or its designee • The contractor shall be responsible for any minor alterations as to ensure the scale is operational