Specifications include, but are not limited to: a)CCTV: The Contractor will supply all equipment and labor to properly inspect sanitary and storm sewers using self-powered CCTV technology. Inspection shall be captured on a DVD with audio details and provide footage and grade data. DVD will become the property of the City of Bonner Springs. b)Inspection Report: The Contractor will provide the Wastewater Division a detailed report the condition of the sewers using descriptions from the Manual of Sewer Condition Classifications (MSCC), version 4. Written reports shall be bound and digitally submitted on a flash drive or DVD. Preferred inspection software is "WinCan". Contractors using alternative software should contact the Wastewater Division prior to submitting the Rate Sheet. c)Method of Inspection: Contractor shall follow NASCCO methods (Appendix A) The pre-cleaning of the sanitary sewers will be performed by Public Works staff. We will have a jet truck available to re-clean or jet and remove debris if needed.