Specifications include, but are not limited to: Replace existing controller with new “Motion Control Engineering” with AC Drive or equivalent. Existing geared machine will be replaced with geared “Hollister Whitney” machine with AC Motor All new hoist ropes New digital AC drive to be installed New code compliant emergency brakes will be installed Replacement of existing governor Existing governor and hoist rope is to be replaced Existing door operator to be replaced with MAC or GAL closed loop operator or equivalent Existing car and hall door equipment (tracks, hangers, header, door clutch, restricted opening device, rollers, gibs, interlocks and door protections device) are all to be replaced. Existing car doors to be replaced Existing car sills to be RETAINED Existing Hoistway Door Equipment (hangers, interlock and closers) shall be replaced. Existing Hoistway doors are to be RETAINED Existing Entrance Frames will be RETAINED Existing door gibs shall be replaced Main car operating panels to be replaced with new code compliant panels New ADA compliant telephone to be installed on car Operating Panel New car position indicators to be installed on Car Operating Panel Existing car exhaust fan to be replaced New code compliant hall buttons and Hall Indicator lanterns will be installed New code compliant Hoistway Access Key Switches are to be installed on the top and bottom landings. New pit switches are to be installed New load weigher to be installed New rope gripper to be installed New car top inspection station to be installed New car top railings to be installed New traveling cable and wiring to be installed New leveling system to be installed Existing toe guard to be replaced Existing car roller guides to be replaced Existing counterweight roller guides to be replaced Existing pit ladder to be replaced All new code required signage at each landing Phase I and Phase II fire fighter service key switches to meet code