Specifications include, but are not limited to: All work for the Ultrathin Bonded Overlay shall comply with KDOT specifications, section 613 (Attachment B). Section 613.2 regarding contractor quality control requirements will not be required. A mix design will need to be submitted to the Engineer for approval before any work can proceed. Section 613.8, Part b. This section in the KDOT specifications does not apply to this project. The emulsified asphalt shall be considered subsidiary to the bid item “HMA Surface (Ultrathin Bonded)(Type A)(PG 64- 22)”. The milling shall consist of using a cold milling machine at least six (6) foot in width. All areas that are edge milled shall transition from 5/8” to 0” in the 6 feet. This will include milling along the outside curb line, medians, and drive entrances. The drive entrances shall transition from 5/8” to 0” in 50’ on either side of the entrance. Transition milling will take place at the beginning and end of the project limits and abutting bridges and intersections. The transition milling shall transition from 5/8” to 0” in the 20 feet. All work for milling will be subsidiary with the bid item “Cold Milling”.