Specifications include, but are not limited to: A. Garage Doors 1) New openings and locations of new commercial garage doors to be installed at the City of Quincy’s Transit Building, which is located at 2020 Jennifer Road, Quincy, IL 62301. 2) On the north side of the Transit Building there will be three (3) new openings created for the installation of three (3) new commercial garage doors and another opening created for one (1) new commercial garage door to be installed on the southeast side of the Transit Building; 3) Commercial grade garage doors will need to have the following: a) Insulating values of R = 14.86 U = .067 b) Section Thickness of 1 5/8” and all sections to be fitted with tube seals to weather-strip each joint; c) Air infiltration of .08 cfm per sq. ft. of door at 15 mph and 26 sound transmission; d) End stiles will be 16 ga and hinges & fixtures will be galvanized steel; B. Garage Door measurements & additional specifications shall be as follows: 1) Garage Door specifications for North Side of Transit Building: • Three (3) garage doors which will be installed on the North side of Transit building; • Door Width shall be 11 ft 2 in • Door Height shall be 12 ft 9 in • Opening Width 11 ft • Opening Height 12 ft 8 in • Door Color: White