Specifications include, but are not limited to: Standard chain-length fencing A.Structural performance: Chain-link fence and gate frameworks shall withstand the design wind loads and stresses for fence height(s) and under exposure conditions indicated according to ASCE/SEI 7. 1. Design Wind Load: 105 mph. a. Minimum Post Size: Determine according to ASTM F 1043 for post spacing not to exceed 10 feet (3 m) for Material Group IA, ASTM F 1043, Schedule 40 steel pipe. B.Lightning protection system: Maximum resistance-to-ground value of 25 ohms at each grounding location along fence under normal dry conditions. C.Chain-link fence fabric: Provide fabric in one-piece heights measured between top and bottom of outer edge of selvage knuckle or twist. 1.Fabric Height: 6 feet (1.8 m). 2.Steel Wire Fabric: Wire with a diameter of 0.192 inch (4.88 mm). a.Mesh Size: 2 inches (50 mm).