Specifications include, but are not limited to: One story 9,000 +/- total SF; combination of brick, stone, stucco and/or hardy siding. Roof – architectural shingles with 30-year warranty; prefinished aluminum box gutters with matching prefinished downspouts that tie into underground drain boot. Three (3) drive-thru bays with Door Engineering Four-Fold Door System (or equal) on all (6) drivethru bay doors; (4) trough type floor drains in each bay; bay floor to be 6” 4,000 PSI reinforced concrete with 6” of GAB; roll-up bay doors to have (2) rows of glass with individual remote openers; EMS storage room, janitorial room, gear laundry room, and (24) gear locker room, each off of bay; (2) water and (2) air hose reels in bay; (6) electric cord reels in bay (one over left side of each apparatus); radiant heaters and Air Hawk exhaust extraction system in bay; drop ceiling with flush-mount LED lights in bay; vinyl coated 2’x4’ drywall ceiling tiles in bay; steel bollards at entrance/exit of apparatus bays; exterior trough drains across/near front bay doors to prevent water entering bay. Single-sided floor plan with all living space on the same side.