Specifications include, but are not limited to: 1. Fully comply with all current ADA requirements (partition stall sizes, grab bars, vanities, plumbing fixtures, dispensers, etc). 2. Remove and replace all dropdown acoustical ceilings to include aluminum grid frames and ceiling tiles. Match existing layout pattern and sizes. Match existing product specifications. 3. Remove and replace all other ceiling items/fixtures/trim kits to include: new sprinkler head trims, new LED light fixtures, alarm system devices, new HVAC vent grills, and new ventilation fans/covers. Match existing layouts/locations and product specifications. 4. Remove all items from the walls and repair/patch all sheetrock wallboard. 5. Remove and replace all bathroom mirrors to include each individual vanity mirror and the full length mirror in the women’s restroom. Each individual vanity mirror shall be replaced with one longer full length vanity mirror.