Specifications include, but are not limited to: •Repair of aluminum covered walkways roofs. •Replace 8 exterior pole-mounted lighting fixtures at the parking lots. Building 01 (Administration Building): •Re-roofing •Mechanical: Replacement of 2 AHU's and 1 CU. •Replace the existing Fire Alarm Panel. •Electrical: Replacement of exterior light fixtures. Building 02 (Media Center): •Re-roofing. •Mechanical: Replacement of 1 AHU. •Electrical: Replacement of exterior light fixtures. Building 03 (Classrooms): •Re-roofing. •Mechanical: Replacement of 4 rooftop a.c. units. •Electrical: Replacement of light fixtures located in the covered walkway. Building 04 (Classrooms): •Re-roofing •Mechanical: Test and Balance of the entire Building. Building 05 (Teacher Planning): •Re-roofing Building 06 (Auditorium): •Re-roofing •Repair 2 damaged exterior concrete columns. •Mechanical: Replacement of 2 exterior condensing units and 2 AHU's. •Electrical: Replacement of the electrical panel serving the building. •Electrical: Replacement of light fixtures located in the covered walkway. Building 07 (Building Support): •Re-roofing. •Mechanical: Replacement of 2 HVAC chillers. •Electrical: Replacement of the switch-gear and panel. •Electrical: Replacement of wall mounted exterior light fixture. Building 08 (Classrooms): •Re-roofing. Building 09 (Classrooms): •Re-roofing. •Mechanical: Replacement of 3 AHU's. •Electrical: Replacement of wall-mounted exterior light fixture. Building 10 (Storage): •Re-roofing, including the replacement of the roof deck. •Electrical: Replacement of electrical panel. Building 11 (Cafeteria): •Re-roofing. •Mechanical: Replacement of 1 AHU and 1 package RTU (rooftop unit). •Mechanical: Replace Kitchen hood exhaust and intake •Electrical: Replacement of transformer and switch-gear. •Electrical: Replacement of 2 distribution panels. Building 12 (Storage): Building 13 (Classrooms): •Re-roofing. •Mechanical: Replacement of 2 exterior condensing units and 2 AHU's.