Specifications include, but are not limited to: • The precast concrete buildings shall have a minimum of 4” walls, 4” roof and an 8” floor. • Two bathrooms one with two toilets and the other with a toilet and a urinal. In each bathroom one toilet must be ADA compliant. • Small dry concession stand/storage area. • Brick Formliner/Stucco on exterior complete (Color to be selected by owner) • Roof covered with 115 Mill EPDM fully adhered to concrete roof with termination bar • Walls and ceiling of each restroom and concession area shall be coated with water based epoxy. (Color to be selected by owner) ; Floor of each restroom shall be coated with Tnemec glaze series 281 non-slip epoxy or approved equal (Color to be selected by owner) • All doors shall be galvanized steel doors with Stainless Steel hinges and mortise lockset with lever. (Color to be selected by owner) • Include all required door weather-stripping, door sweeps, and necessary thresholds. • Hot water heater • Porcelain toilets with plastic seats with manual flushometers • Porcelain sinks with metering faucets • Porcelain urinal with manual flushometer • Enough amperage for a 240/120 volt Main Circuit Breaker Panelboard • All lights must be LED fixtures with photocell • Exit/emergency combination fixtures .