Specifications include, but are not limited to: Review and verify the attached field measurement spreadsheets, accurately complete the newly formatted required table(Appendix C) and obtain permit for 554 LA County-owned catch basins (City will pay permit costs directly to L.A. County) per requirements of Los Angeles County Department of Public Works. EA 554 2 Photographic documentation of catch basins before and after per 900-1.5 of Technical Specs. LS 1 3 Clean out existing catch basins and dispose of all debris EA 554 4 Remove existing fixed screens and install protection bars EA 3 5 Furnish and install automatic retractable screen (ARS) width (W) equal or less than 5 feet EA 3 6 Furnish and install automatic retractable screen (ARS) width (W) greater than 5 feet but equal or less than 8 feet EA 3 Furnish and install automatic retractable screen (ARS) width (W) greater than 8 feet or less than 15 feet EA 3 8 Furnish and install automatic retractable screen (ARS) width )W) greater than 15 feet but equal or less than 22 feet EA 3 9 Furnish and install automatic retractable screen (ARS) width (W) greater than 22 feet but equal or less than 29 feet EA 3 10 Furnish and install connector pipe screen (CPS), including flow deflector on top of the CPS structure, for outlet pipe sizes 8”-24” EA 534