Specifications include, but are not limited to: Removal of existing traffic signal controller cabinets and foundations and construction of foundations for installation of new complete ATMS 332L cabinets; providing and maintaining temporary traffic signal systems at each location during construction, removal of existing mast arm signal poles and foundations; installation of new foundations and mast arm signal poles; installation of conduit, pull boxes, wiring, video detection systems, Axis IP CCTV systems, audible pedestrian system (APS) push buttons and signs, and LED safety lighting; removal and replacement of vehicle signal indications; removal and replacement of concrete curb, gutter, sidewalk, and ADA ramps, and installation of truncated domes; removal and modification of a landscaped median nose, replacement of AC pavement; utility/pull box adjustments and other items not mentioned here, but are required by the plans and the Special Provisions.