Specifications include, but are not limited to: Repairing cracks in areas of the exterior CMU walls on Building B and two interior concrete walls in Building A situated on the interior West wall of the Power Control Center and North wall at the Northeast first floor office. Repair requirements include: -Cracks in the CMU walls shall be repaired by structural epoxy grout injection. This would occur at the west wall at the dispatch area and the north wall at the north east first floor office. -The repair will include removing the interior wall finishes adjacent to the cracks to a width of 2" (2 inches). -Installing mechanical seals over the cracks. -Pressure injection of grout into the crack to re-bond the CMU and grout. -Refinishing the area to match existing surface, fulling 2: cut and repainting with Low VOC paint. Paint color information will be provided.