Specifications include, but are not limited to: Air purity shall meet or exceed the standards of the Compressed Gas Association Specification G7.1 for grade “E” breathing air and the standards of NFPA 1500. Pressure vessels shall be designed and fabricated in accordance with either the applicable DOT or ASME codes. All tubing shall meet NFPA, SAE, JIC and ANSI standards. All valves shall meet the applicable national codes such as those of the Bureau of Explosives, DOT and CGA. The entire air system shall meet all requirements established by the Occupational Safety and Health Act, otherwise known as OSHA. Purification systems shall be constructed in accordance with section VIII of the ASME code for unfired pressure vessels. The compressor system manufacturer shall have an ISO 9001:2015 quality management system standard approval on the design and/or manufacture process. The (6000 psi, 20 HP)system shall be mounted on a vertical steel frame designed for both the static and dynamic loads of the system and of sufficient size to adequately accommodate all of the system’s components. The arrangement of components on the frame shall permit unrestricted cooling air flow to the compressor and prime mover and provide access for operation and maintenance. The system shall be designed for operation indoors with room temperatures ranging between 40°F and 115°F. Installation shall not require a special foundation; however, it is the responsibility of the purchaser to ensure the installation site has a solid and level foundation that can support the weight of the system. The purchaser must also ensure the availability of a qualified source of air for the intake of the compressor and adequate ventilation.