Specifications include, but are not limited to: • Install GFCIs within 6' of a water source (within the same room) to include Hi-Rise laundry rooms. • Install single-pole outlets where designed for major appliances (refrigerator, kitchen range, washing machines, etc.) • Install combination smoke/CO2 detectors: each level of the unit (including basement) must have a detector, as well as a detector in each sleeping room (and outside each bedroom). • If mounted on ceiling, they should be more than 4" from wall. • If mounted on wall, they should be between 4" and 12" from ceiling. • Basement combination smoke/CO2 detectors should be installed on the ceiling at the bottom of the stairs leading to the next level. • On levels without bedrooms, the combination smoke/CO2 detector should be installed in the main living areas or near the stairway leading to the upper level (or in both) ▪ *NOT within 10 feet of a cooking appliance ▪ *NOT within 3 feet of Ceiling Fans, Air Ducts, Exterior Doors, or Windows where drafts might interfere with their operation • All combination smoke/CO2 detectors, which are solely battery-operated, must have sealed, tamper-proof batteries. • Install/replace smoke detectors, as necessary. • All smoke detectors, which are solely battery-operated, must have sealed, tamper-proof batteries. • Install/replace CO2 detectors, as necessary. • All CO2 detectors, which are solely battery-operated, must have sealed, tamper-proof batteries.