Specifications include, but are not limited to: NEW LINEAR FLOOR DRAIN WITH REMOVEABLE STEEL GRATING, APPROXIMATELY 75'-0" X 10'-0" (LOCATE AS CLOSE AS POSSIBLE TO WHERE TRAIN TRACKS USED TO BE, SLIGHTLY VISIBLE WHERE CONCRETE WAS POURED AFTER TRACKS REMOVED); SLOPE DRAIN SLIGHTLY TOWARD BACK OF BUILDING, CONNECT TO SEWER IN S WARREN STREET; DRAIN TO HAVE SAND AND OIL SEPARATORS PRIOR TO ENTERING SEWER SYSTEM WALL OR CEILING MOUNT GAS SHOP HEATER WITH DIRECT VENT TO THE EXTERIOR; SIZE HEATER TO HEAT HALF TO TWO-THIRDS OF APPROXIMATELY 6,000 SF OF GARAGE SPACE; AVERAGE CEILING HEIGHT OF 23'-0" INSULATE WALLS AND CEILINGS, TYP. WITH CORBOND; PAINTED FINISH, CONTRACTOR TO CONFIRM WITH OWNER FOR PAINT COLORS SHEET OVER EXISTING WINDOWS BEFORE CORBOND INSULATION ALL NEW SHOP LIGHTS - 48"X14" LED HIGH BAY (OR EQUIVALENT); AT GARAGE DOORS, SURFACE MOUNT ON STRUCTURE ABOVE; ALL OTHER AREAS, SUSPEND FIXTURE 18" MIN. FROM STRUCTURE ABOVE; STAGGER MOUNT (2) PER BAY - SEE PLANS FOR APPROX. LOCATIONS AND SWITCHING; SWITCHING AND QUANTITY SUBJECT TO CHANGE PROVIDE EMERGENCY LIGHT/EXIT LIGHT COMBOS CENTERED ABOVE DOOR; PROVIDE EMERGENCY LIGHTING IN NEW LOCKER ROOM 208 EXISTING LIGHTING SHOULD WORK IN NEW SHOWER 207, EDIT AS NEEDED BASED ON BUILD-OUT MATCH EXISTING LIGHT FIXTURE IN NEW SHOWER 207 FOR NEW LIGHTING IN NEW LOCKER ROOM 208; SURFACE MOUNT LED TO REPLACE BAR BULB FIXTURE; USE EXISTING SWITCH ADD DUPLEX OR QUAD OUTLETS SEE PLANS; DUPLEX IN WET AREAS TO BE GFI; ALL 18" AFF, MIN.